Cooperation Contact
0755-25336260
info@cnsyd.com
High Voltage Products
  Home > Products > High Voltage Products  > Tuning reactor
SYD_LAN_0121:

BCJ series high voltage dry-type series reactors suitable for 635KV power system,in parallel with a capacitor in series with the LC circuit to suppress the grid voltage waveform distortion,control flow through the capacitor harmonics and inrush current limiting capacitor combination gates.

  • Brief introduction
  • Innovative Features
  • Parameter
  • Controller parameters
  • Similar products
BCJ series high voltage dry-type series reactors suitable for 635KV power system,in parallel with a capacitor in series with the LC circuit to suppress the grid voltage waveform distortion,control flow through the capacitor harmonics and inrush current limiting capacitor combination gates.
Using a dedicated computer-aided design software, according to customer requirements, the structure and parameters of fast and accurate determination of the product;
Reasonable structure design, the impact of potential distribution uniformity, strong short-circuit current withstand capability
Optimization of the core flux density and current density wire, low noise, low loss, long life, low temperature
Reactor core coil using epoxy resin casting, with high dynamic and thermal stability, dielectric strength, high mechanical strength, high reliability, low magnetic leakage, the Council lowered, small, very suitable for placement in the cabinet within
Hollow reactor winding wire abdominal pack a variety of small cross-section of the winding, good linearity, has a strong ability to limit short-circuit current, insulation performance, low loss, flexible installation, can be placed on a three-phase level, can also be stacked dress
Rated power:50Hz
Phase:single or three phase
System rated voltage:6,10,35KV
0.1%, 0.3%, 0.5%, 1%, is to limit the inrush current
4.5%, 5%, 6%, and for limiting inrush current 5 times and more harmonic suppression
12%, 13%, is used to limit inrush current and harmonic suppression three times and more
Rated voltage: Rated voltage terminal of the reactor K value of the rated voltage of the capacitor package (K reactance ratio )
Rated capacity: three-phase reactor rated capacity of supporting the rated capacity of the capacitor bank value of K (K is the reactance ratio ) , single -phase reactor rated capacity of one-third of the rated capacity of the three-phase
At rated current , rated reactance ratio K ≥ tolerance reactance reactor 4.5% for 0 - +5%; K ≤ 1% of the reactor , its value is 0 - +10%
For three-phase reactor or by a single-phase reactor consisting of a three-phase reactor group, reactance per phase does not exceed ± 2% average of the three
Core reactors and K ≤ 1% of the core reactor can withstand 25 times the rated current ongoing 2s role, without generating any heat and mechanical damage; K ≥ 4.5% of dry hollow reactor can withstand reactance rate Countdown 2s times the rated continuous current role, without any thermal and mechanical damage.

Rated voltage 7.2KV

Type

Power output(kvar

Inductance(mH

Rated current(A

KRV 200-P7-7.2

200

42.75

19

KRV 400-P7-7.2

400

21.38

39

KRV 600-P7-7.2

600

14.25

57

 

Rated voltage 12KV

Type

Power output(kvar

Inductance(mH

Rated current(A

KRV 300-P7-12

300

78.65

17

KRV 600-P7-12

600

39.33

35

KRV 900-P7-12

900

26.22

52

 